Examples



mdbootstrap.com



 
Article
2018

A Potentiometric Sensor for Determination of Doxycycline Hydrochloride in Pharmaceutical Preparation and Biological Fluids


T. A. AliT. A. Ali, G. G. MohamedG. G. Mohamed, A. Z. El-SonbatiA. Z. El-Sonbati, M. A. DiabM. A. Diab, A. M. ElkfassA. M. Elkfass
Russian Journal of Electrochemistry
https://doi.org/10.1134/S1023193518120029
Abstract / Full Text

This article focused on the construction and characteristics of novelty and sensitivity of modified carbon paste electrodes for determination of doxycycline hydrochloride (DC.HCl) in urine, serum and pharmaceutical preparations. It was based on the incorporation of α-cyclodextrine (α-CD) and multi-walled carbon nanotube (MWCNT) ionophores which improved the characteristics of the electrodes with tricresylphosphate (TCP) (electrode I) and o-nitrophenyloctylether (o-NPOE) (electrode II) as plasticizers, respectively. The constructed electrodes, at optimum paste composition, exhibited good Nernstian response for determination of doxycycline hydrochloride over a linear concentration range from 1.0 × 10–7 to 1.0 × 10–2 and 1.22 × 10–7 to 1.0 × 10–2 mol L–1 with detection limit of 1.0 × 10–7 and 1.22 ×10–7 mol L–1 and with slope values of (58.7 ± 0.2) mV decade–1 and (58.0 ± 0.6) mV decade–1, for modified carbon paste electrodes (MCPEs; electrodes I and II), respectively. The results showed fast dynamic response time (about 6–7 s) and long lifetime in the range from 4 to 5 months where the response of the electrodes was not affected by pH variation within the range from 2 to 8 and 2 to 7.5 for electrodes I and II, respectively. Electrodes I and II showed high selectivity for doxycycline hydrochloride with respect to a large number of interfering species including foreign inorganic, organic species, excipients and the fillers added to the pharmaceutical preparation. The constructed electrodes were successfully applied for determination of DC.HCl in pure form, its pharmaceutical preparations and biological fluids (urine and serum) using standard addition, calibration curves and potentiometric titration methods. The results obtained using these potentiometric electrodes were comparable with those obtained using official method. The results were satisfactory with excellent percentage recovery comparable or better than those obtained by other routine methods.

Author information
  • Egyptian Petroleum Research Institute (EPRI), Cairo, 11727, EgyptT. A. Ali
  • Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, EgyptG. G. Mohamed & A. M. Elkfass
  • Chemistry Department, Faculty of Science, Damietta University, Damietta, EgyptA. Z. El-Sonbati & M. A. Diab
References
  1. Tashkhourian, J., Absalan, G., Jafari, M., and Zare, S., A rapid and sensitive assay for determination of doxycycline using thioglycolic acid-capped cadmium telluride quantum dots, Spectrochim. Acta, Part A, 2016, vol. 152, pp. 119–125.
  2. Kogawa, A.C., Salgado, H.R., Amenomori, N., Ishimoto, H., Nagata, T., Mukae, H., and Kohno, S., Doxycycline hyclate: a review of properties, applications and analytical methods, Int. J. Life Sci. Pharma Res., 2012, vol. 2, no. 4, pp. 11–25.
  3. Shariati, S., Yamini, Y., and Esrafili, A., Carrier mediated hollow fiber liquid phase microextraction combined with HPLC–UV for preconcentration and determination of some tetracycline antibiotics, J. Chromatogr. B, 2009, vol. 877, no. 4, pp. 393–400.
  4. Fujita, H., Sakamoto, N., Ishimatsu, Y., Kakugawa, T., Hara, S., Hara, A., Amenomori, M., Ishimoto, H., Nagata, T., Mukae, H., and Kohno, S., Effects of dox-ycycline on production of growth factors and matrix metalloproteinases in pulmonary fibrosis, Respiration, 2011, vol. 81, no. 5, pp. 420–430.
  5. Kładna, A. and Aboul-Enein, H.Y., Clinical applications of non-antimicrobial actions of tetracyclines in inflammatory diseases, Curr. Drug Ther., 2011, vol. 6, no. 4, pp. 233–239.
  6. Maaland, M.G., Papich, M.G., Turnidge, J., and Guardabassi, L., Pharmacodynamics of doxycycline and tetracycline against staphylococcus pseudintermedius: Proposal of canine-specific breakpoints for doxycycline, J. Clin. Microbiol., 2013, vol. 51, no. 11, pp. 3547–3554.
  7. Patel, M.R., Patel, A.A., Prajapati, L.M., and Patel, N.M., Formulation and evaluation of doxycycline hydrochloride delayed release enteric coated tablets, Pharm. Lett., 2012, vol. 4, no. 1, pp. 249–255.
  8. Ali, T.A., Mohamed, G.G., Al-Sabagh, A.M., and Migahed, M.A., A new screen-printed ion selective electrode for determination of citalopram hydrobromide in pharmaceutical formulation, Fenxi Huaxue (Chin. J. Anal. Chem.), 2014, vol. 42, no. 4, pp. 565–572.
  9. Ali, T.A., Mohamed, G.G., Omar, M.M., and Abdrabou, V.N., Improved determination of mebeverine hydrochloride in urine, serum and pharmaceutical preparations utilizing a modified carbon paste electrode, Int. J. Electrochem. Sci., 2015, vol. 10, no. 3, pp. 2439–2454.
  10. Tsarfati, E.M. and Sutherland, R., Whipple’s disease, Br. J. Hosp. Med., 2016, vol. 77, no. 6, pp. C82–C85.
  11. Raoult, D., Chronic Q fever: Expert opinion versus literature analysis and consensus, J. Infect., 2012, vol. 65, no. 2, pp. 102–108.
  12. Angelakis, E., Armstrong, N., Nappez, C., Richez, M., Chabriere, E., and Raoult, D., Doxycycline assay hair samples for testing long-term compliance treatment, J. Infect., 2015, vol. 71, no. 5, pp. 511–517.
  13. Ward, J.E., Ren, R., Toraldo, G., SooHoo, P., Guan, J., O’Hara, C., Jasuja, R., Trinkaus-Randall, V., Liao, R., and Connors, L.H., Doxycycline reduces fibril formation in a transgenic mouse model of AL amyloidosis, Blood, 2011, vol. 118, no. 25, pp. 6610–6617.
  14. Fan, Q., Sirkar, K.K., Wang, Y., and Michniak, B., In vitro delivery of doxycycline hydrochloride based on a porous membrane-based aqueous–organic partitioning system, J. Cntrolled Rlease, 2004, vol. 98, no. 3, pp. 355–65.
  15. Yang, F., Liu, H., Li, M., Ding, H., Huang, X., and Zeng, Z., Use of a Monte Carlo analysis within a physiologically based pharmacokinetic model to predict doxycycline residue withdrawal time in edible tissues in swine, Food Addit. Contam., Part A, 2012, vol. 29, no. 1, pp. 73–84.
  16. Lotfy, H.M., Hegazy, M.A., Mowaka, S., and Mohamed, E.H., Validated spectrophotometric methods for simultaneous determination of Omeprazole, Tinidazole and Doxycycline in their ternary mixture, Spectrochim. Acta, Part A, 2016, vol. 153, pp. 321–332.
  17. Zaher, F.A. and Soliman, H.M., Biodiesel production by direct esterification of fatty acids with propyl and butyl alcohols, Egypt. J. Pet., 2015, vol. 24, no. 4, pp. 439–443.
  18. Arida, H., Hassan, R., and El-Naggar, A., Quality assessment of honey using modern analytical tools, Anal. Lett., 2012, vol. 45, no. 11, pp. 1526–1536.
  19. Ali, T.A., Mohamed, G.G., Aglan, A.A., and Heakal, F.E.T., RP-HPLC Stability-indicating method for estimation of irbesartan and hydrochlorothiazide in bulk and pharmaceutical dosage form, Fenxi Huaxue (Chin. J. Anal. Chem.), 2016, vol. 44, no. 1, pp. e1601–e1608.
  20. Palamy, S. and Ruengsitagoon, W., A novel flow injection spectrophotometric method using plant extracts as green reagent for the determination of doxycycline, Spectrochim. Acta, Part A, 2017, vol. 171, pp. 200–206.
  21. Wang, P., Hong, Q., Liu, M., Yuan, H., Peng, Y., and Zhao, J., Rapid detection of doxycycline content in duck meat by using silver nanoparticles and alkylphenols polyoxyethylene enhanced fluorescence of europium complex, Spectrosc. Lett., 2016, vol. 49, no. 9, pp. 563–567.
  22. Attia, M.S., Mahmoud, W.H., Ramsis, M.N., Khalil, L.H., Othman, A.M., Hashem, S.G., and Mostafa, M.S., Spectrofluorimetric assessment of doxycycline hydrochloride in pharmaceutical tablets and serum sample based on the enhancement of the luminescence intensity of the optical sensor Sm3+ ion, J. Fluoresc., 2011, vol. 21, no. 4, pp. 1739–1748.
  23. Kumar, R. and Agrawal, Y.K., Recent applications of analytical techniques for counterfeit drug analysis: A review, Int. J. Pharm. Tech. Res., 2014, vol. 6, no. 2, pp. 646–665.
  24. Akl, Z.F. and Ali, T.A., Highly sensitive potentiometric sensors for thorium ions detection using morpholine derivative self-assembled on silver nanoparticles, RSC Adv., 2016, vol. 6, no. 81, pp. 77854–77862.
  25. Tashkhourian, J., Absalan, G., Jafari, M., and Zare, S., A rapid and sensitive assay for determination of doxycycline using thioglycolic acid-capped cadmium telluride quantum dots, Spectrochim. Acta, Part A, 2016, vol. 152, pp. 119–125.
  26. Shoukry, A. and Badawy, S., Determination of tetracycline and related compounds using plastic membrane ion-selective electrodes, Microchem. J., 1987, vol. 36, no. 1, pp. 107–112.
  27. Ali, T.A., Mohamed, G.G., Omar, M.M., and Hanafy, N.M., Construction and performance characteristics of chemically modified carbon paste electrodes for the selective determination of Co(II) ions in water samples, J. Ind. Eng. Chem., 2015.
  28. Ali, T.A., Aglan, R.F., Mohamed, G.G., and Mourad, M.A., New chemically modified screenprinted electrode for Co(II) determination in different water samples, Int. J. Electrochem. Sci., 2014, vol. 9, no. 4, pp. 1812–1826.
  29. Ali, T.A., Azzam, E.M.S., Hegazy, M.A., El-Farargy, A.F.M., and Abd-elaal, A.A., Zinc(II) modified carbon paste electrodes based on self-assembled mercapto compounds-gold-nanoparticles for its determination in water samples, J. Ind. Eng. Chem., 2014, vol. 20, no. 5, pp. 3320–3328.
  30. Ali, T.A., Eldidamony, A.M., Mohamed, G.G., and Abdel-Rahman, M.A., A novel potentiometric sensor for selective determination of dodecyl(2-hydroxyethyl)-dimethylammonium bromide surfactant in environmental polluted samples, Int. J. Electrochem. Sci., 2014, vol. 9, no. 8, pp. 4158–4171.
  31. Ali, T.A., Eldidamony, A.M., Mohamed, G.G., and Elatfy, D.M., Construction of chemically modified electrode for the selective determination of copper(II) ions in polluted water samples based on new β-cyclodextrine and 1,4-bis(6-bromohexyloxy)benzene ionophores, Int. J. Electrochem. Sci., 2014, vol. 9, no. 5, pp. 2420–2434.
  32. Ali, T.A., Farag, A.A., and Mohamed, G.G., Potentiometric determination of iron in polluted water samples using new modified Fe(III)-screen printed ion selective electrode, J. Ind. Eng. Chem., 2014, vol. 20, no. 4, pp. 2394–2400.
  33. Ali, T.A., Hassan, A.M.E., and Mohamed, G.G., Manufacture of lead-specific screen-printed sensor based on lead schiff base complex as carrier and multiwalled carbon nanotubes for detection of Pb(II) in contaminated water tests, Int. J. Electrochem. Sci., 2016, vol. 11, pp. 10732–10747.
  34. Ali, T.A. and Mohamed, G.G., Determination of Mn(II) ion by a modified carbon paste electrode based on multi-walled carbon nanotubes (MWCNTs) in different water samples, Sens. Actuators, B, 2014, vol. 202, pp. 699–707.
  35. Ali, T.A. and Mohamed, G.G., Potentiometric determination of La(III) in polluted water samples using modified screen-printed electrode by self-assembled mercapto compound on silver nanoparticles, Sens. Actuators, B, 2015, vol. 216, pp. 542–550.
  36. Ali, T.A. and Mohamed, G.G., Multi-walled carbon nanotube and nanosilica chemically modified carbon paste electrodes for the determination of mercury(II) in polluted water samples, Anal. Methods, 2015, vol. 7, no. 15, pp. 6280–6289.
  37. Ali, T.A. and Mohamed, G.G., Modified screenprinted ion selective electrodes for potentiometric determination of sodium dodecylsulfate in different samples, J. AOAC Int., 2015, vol. 98, no. 1, pp. 116–123.
  38. Ali, T.A., Mohamed, G.G., El-Dessouky, M.M., and Ragheb, R.M., Highly selective potentiometric determination of 1-dodecyl-5-methyl-1H-benzo[d][1,2,3]triazol-1-ium bromide surfactant in polluted water samples using 1,4-bis-(8-Mercaptooctyloxy)-benzene ionophore, Int. J. Electrochem. Sci., 2015, vol. 10, no. 6, pp. 4820–4831.
  39. Ali, T.A., Mohamed, G.G., El-Dessouky, M.M.I., Abou El Ella, S.M., and Mohamed, R.T.F., Modified carbon paste ion selective electrodes for the determination of iron(III) in water, soil and fish tissue samples, Int. J. Electrochem. Sci., 2013, vol. 8, no. 1, pp. 1469–1486.
  40. Ali, T.A., Mohamed, G.G., El-Dessouky, M.M.I., Abou El-Ella, S.M., and Mohamed, R.T.F., Modified screen-printed electrode for potentiometric determination of copper(II) in water samples, J. Solution Chem., 2013, vol. 42, no. 6, pp. 1336–1354.
  41. Ali, T.A., Mohamed, G.G., and Farag, A.H., Electroanalytical studies on Fe(III) ion-selective sensors based on 2-methyl-6-(4-methylenecyclohex-2-en-1-yl)hept-2-en-4-one ionophore, Int. J. Electrochem. Sci., 2015, vol. 10, no. 1, pp. 564–578.
  42. Ali, T.A., Mohamed, G.G., Azzam, E.M.S., and Abd-Elaal, A.A., Thiol surfactant assembled on gold nanoparticles ion exchanger for screen-printed electrode fabrication. Potentiometric determination of Ce(III) in environmental polluted samples, Sens. Actuators, B, 2014, vol. 191, pp. 192–203.
  43. Ali, T.A., Mohamed, G.G., and Othman, A.R., Design and construction of new potentiometric sensors for determination of copper(II) ion based on copper oxide nanoparticles, Int. J. Electrochem. Sci., 2015, vol. 10, no. 10, pp. 8041–8057.
  44. Sun, Xian Xiang, Aboul-Enein, and Hassan, Y., Internal solid contact sensor for the determination of doxycycline hydrochloride in pharmaceutical formulation, Talanta, 2002, vol. 58, pp. 387–396.
  45. Mohamed, G.G., Ali, T.A., El-Shahat, M.F., Al-Sabagh, A.M., and Migahed, M.A., New Screenprinted ion-selective electrodes for potentiometric titration of cetyltrimethylammonium bromide in different civilic media, Electroanalysis, 2010, vol. 22, no. 21, pp. 2587–2599.
  46. Mohamed, G.G., Ali, T.A., El-Shahat, M.F., Al-Sabagh, A.M., Migahed, M.A., and Khaled, E., Potentiometric determination of cetylpyridinium chloride using a new type of screen-printed ion selective electrodes, Anal. Chim. Acta, 2010, vol. 673, no. 1, pp. 79–87.
  47. Mohamed, G.G., Ali, T.A., El-Shahat, M.F., Migahed, M.A., and Al-Sabagh, A.M., Novel screenprinted electrode for the determination of dodecyltrimethylammonium bromide in water samples, Drug Test. Anal., 2012, vol. 4, no. 12, pp. 1009–1013.
  48. Mohamed, G.G., El-Shahat, M.F., Al-Sabagh, A.M., Migahed, M.A., and Ali, T.A., Septonex-tetraphenylborate screen-printed ion selective electrode for the potentiometric determination of Septonex in pharmaceutical preparations, Analyst, 2011, vol. 136, no. 7, pp. 1488–1495.
  49. Füglein, R., Bräuchle, Ch., and Hampp, N., Ionselective electrodes for the determination of the antibiotic drug chlortetracycline, Anal. Sci., 1994, vol. 10, pp. 959–962.
  50. Ali, T.A., Soliman, M.H., Mohamed, G.G., Farag, A.B., and Samah, M.K., Development of a new modified screen-printed and carbon paste electrodes for selective determination of cetyltrimethylammonium bromide in different water samples, Int. J. Electrochem. Sci., 2015, vol. 10, no. 4, pp. 3192–3206.
  51. Frag, E.Y.Z., Ali, T.A., Mohamed, G.G., and Awad, Y.H.H., Construction of different types of ionselective electrodes, characteristic performances and validation for direct potentiometric determination of orphenadrine citrate, Int. J. Electrochem. Sci., 2012, vol. 7, no. 5, pp. 4443–4464.
  52. Khaled, E., Mohamed, G.G., and Awad, T., Disposal screen-printed carbon paste electrodes for the potentiometric titration of surfactants, Sens. Actuators, B, 2008, vol. 135, no. 1, pp. 74–80.
  53. Ali, T.A., Saber, A.L., Mohamed, G.G., and Bawazeer, T.M., Determination of Cr(III) ions in different water samples using chromium(III)-sensor based on N-[4-(dimethylamino) benzylidene]-6-nitro-1,3-benzothiazol-2-amine, Int. J. Electrochem. Sci., 2014, vol. 9, no. 9, pp. 4932–4943.
  54. Ali, T.A., Soliman, M.H., and Mohamed, G.G., Electrochemical determination of N-(1,1,2,2-tetrahydroperfluorooctyl)-N,N-dimethylammonium chloride surfactant in different water samples using modified screen-printed electrode, Int. J. Electrochem. Sci., 2016, vol. 11, no. 2, pp. 1055–1069.
  55. Vinod, G.K., Arunima Agarwal, N., and Barkha, S.S., Recent advances on potentiometric membrane sensors for pharmaceutical analysis, Comb. Chem. High Throughput Screening, 2011, vol. 14, pp. 284–302.
  56. Ali, T.A., Mohamed, G.G., and Said, A.H., Construction and performance characteristics of modified screen printed and modified carbon paste sensors for selective determination of Cu(II) ion in different polluted water samples, Chem. Eng. Commun., 2016, vol. 203, no. 6, pp. 724–735.
  57. Wei, X-P., Wu, F., and Li, J.-P., Highly sensitive determination of doxycycline hydrochloride by molecularly imprinted sensor based on gate-controlled effect, Chin. J. Anal. Lab., 2013, vol. 8, pp. 6–8.
  58. Aronson, J.K., Meyler`s Side Effects of Drugs: International Encyclopedia of Adverse Drug Reactions and Interactions, 15th ed., Oxford: Elsevier, 2006, pp. 3330–3342.
  59. Brunton, L.L., Lazo, J.S., and Parker, K.L., Goodman and Gilman: As Base Farmacologicas Daterapeutica, 11st ed., Rio de Janeiro: McGraw Hill Interamericana do Brasil, 2006.
  60. Martindale, The Complete Drug Reference, 36th ed., London: Pharmaceutical Press, 2009, pp. 257, 659.
  61. Ramesh, P.J., Basavaiah, K., Tharpa, K., Vinay, K.B., and Revanasiddappa, H.D., Development and validation of RP-HPLC method for the determination of doxycycline hyclate in spiked human urine and pharmaceuticals, J. Pre-Clinical Clinical Res., 2010, vol. 4, pp. 101–107.
  62. Yellin, A., Doxycycline for malignant effusions, Ann. Thorac. Surg., 1994, vol. 57, p. 1053.